China Custom High Efficiency Motor with Best Sales

Product Description

Solution Brief
E-MAX motor is the unique designed permanent CZPT synchronous motor dependent on the IEC norm. E-MAX PMSM will be employed for next generation which need far more vitality saving solution. CZPT IE4 variable speed AC motor (IEC60034-30-2-2016).

E-MAX motor is the 1st technology of CZPT EC motor. E-MAX has led to build the next technology of technologies in motor performance and efficiency.
E-MAX motor contain 2 collection:
E-Max professional
IEC Frame 71 to ninety permanent CZPT synchronous motor built-in push
E-Max Industrial
IEC Frame seventy one to 132 everlasting CZPT synchronous motor

E-Max Professional sequence (ECI series)
 

Model Body Rated Output Output Optimum
size torque @1500rpm @3000rpm velocity
  (Nm)** (kW) (kW) (rpm)
T71ECI01X36 71 one.2 .2 .41 3600
T71ECI02X36 2.four .41 .eighty two 3000
T71ECI03X18 three.two .fifty five 1800
T90ECI03X36 90 3.two .55 one.one 3600
T90ECI05X30 four.8 .seventy five 1.five 3000
T90ECI07X18 seven one.1 1800

** The rated torque is primarily based on the motor CZPT approach. The depth torque you should see knowledge sheet.
E-Max Industrial Motor Push Perform
CW/CCW chooseStart-end terminal0-10VDC speed controlRS485 ModbusSpeed hand manage by adjustable resistanceSpeed feedback
E-Max Industrial series (EC collection)

Model Body Rated Output Output Greatest
dimensions torque @15000rpm @3000rpm velocity
  (Nm)** (kW) (kW) (rpm)
T71EC01X36 71 one.2 .two .forty one 3600
T71EC02X36 2.four .forty one .82 3600
T71EC03X36 three.2 .fifty five one.one 3000
T90EC03X36 90 3.2 .55 one.one 3600
T90EC05X36 4.eight .seventy five 1.5 3600
T90EC07X36 7 one.one 2.two 3600
T100EC10X36 100 nine.5 1.five three 3600
T100EC14X36 fourteen two.2 4 3600
T100EC19X30 19.1 3 five.5 3000
T132EC26X30 132 twenty five.5 4 7.5 3000
T132EC35X30 35 5.5 11 3000
T132EC48X30 forty seven.7 7.5 fifteen 3000
T132EC59X30 fifty eight.nine 9.2 18.five 3000
T132EC70X30 70 11 22 3000

** The rated torque is based mostly on the motor CZPT strategy. The element torque please see info sheet.

Effectiveness class
E-MAX motor has extremely-substantial efficiency each at complete load and gentle load. The flat efficiency curve can preserve much more power when the motor generate the admirer or pump in CZPT discipline.
Evaluate to IE4 motor effectiveness class E-MAX

E-Max Business collection

** Program performance include the motor and generate performance.

E-Max Industrial sequence

** Effectiveness is only motor effectiveness.

Design number nomenclature
T  90  EC  03  V  36  C2  B14  P  T1
1   2   3    4  5   6   7    8    9  ten
 

Place Character Description
1 “T” Product system
2 “90” Frame measurement: IEC 90#
three “EC” EC: long lasting CZPT motor
ECI: long term CZPT motor with integrated drvie
4 “03” Rated torque
5 “V” Cooling approach:
G = Common purposes, with fan and supporter hood. IC411
V = Air flow purposes, CZPT supporter and enthusiast hood.
six “36” Greatest velocity: 3600 rpm
seven C2 Energy line link method:
T1 = Terminal box on leading
T2 = Terminal box on NDE
C1 = No terminal box, electricity line from housing
C2 = No terminal box, power line from NDE
eight B14 Mounting technique:
B3, B14, B5, B34, B35
nine P P = Slid rail
10 T1 Voltage code:
T1: 3 stage 360-440 V
T2: 3 phase 200-240 V
S1: 1 period two hundred-240 V
S2: 1 period a hundred and fifteen V

VFD thought
PMSM should generate by the VSD. The motor are not able to connect to the typical AC electricity immediately. The VSD can be the industrial generate with vector manage or PM motor control manner. VSD need to be set up the proper motor parameter (see beneath desk). The element parameters can be locate in the design knowledge sheet.

Power select consideration
       The electrical power and torque in previously mentioned product listing is the rated electricity or torque when the motor has not any CZPT strategy (IC410). If the motor cooled by the wheel or the load the motor electricity can be bigger. The element operating range make sure you see depth design knowledge sheet. Under chart is a sample to make a decision the electricity at distinct CZPT issue.

Technology:

  1. Knowledgeable on the fan, pump, compressor and motion application with long lasting CZPT motor design
  2. Motor design developing and simulation, overall performance calculation, sounds optimization
  3. Motor material databases: silicon steel, magnet, copper, aluminum
  4. Substantial precision take a look at gear and instrument

              
 

Production and high quality control:

  1. Computerized winding machine to get far better consistency
  2. Electrical take a look at products
  3. Magnetic flux checking

 

Induction motors, also known as asynchronous motors, use the electromagnetic induction produced by the magnetic field of the stator to generate recent in the rotor, therefore making torque. These motors do not operate at a pace in sync with the present, that’s why the title. They use the phenomenon of electromagnetic induction to transform electrical strength into mechanical energy. Induction motor rotors are the most typical sort of AC motor found in pumps, compressors, and other devices of all varieties.
An AC motor is a kind of motor that makes use of the phenomenon of electromagnetic induction. AC energy drives the motor. It is a recent that periodically reverses direction and changes its magnitude of the present more than time. This present is the opposite of a direct existing or “DC” which flows in only one path. AC motors can supply a reasonably successful way to produce mechanical power from a simple electrical enter sign.

China Custom High Efficiency Motor     with Best Sales